Key points in selecting equipment for NVO and BVO selection
Before choosing operating conditions for NVO and BVO selection, define the observable material result and the actual load.
Compare NVO and BVO fan modes and pressure transitions using powder or tray loads as appropriate.
Equipment decisions
-
Describe scale-up using usable tray area, part layers, spacing and thermal load per batch; nominal-volume ratios do not directly predict throughput.
-
Retain the material endpoint and sample-temperature window from laboratory trials, and remeasure heating, evacuation, purge and cooling times in the larger chamber.
-
Compare lab and pilot results at the most challenging load positions, then assess accepted output per batch and complete cycle time.
Trial and acceptance
Record the initial sample condition, loading layout, recipe version and raw measurements. Agree the acceptance endpoint before the trial; repeat at challenging load positions and compare the finished material result.
Catalogue comparison
Candidate models in the current catalogue: ESC-NVO1000-T6, ESC-NVO125-T6, ESC-NVO216-T6, ESC-NVO27-T6. These are comparison candidates, subject to the process checks above.
The following specifications apply only to the models listed:
- ESC-NVO1000-T6: Internal Chamber Dimensions: 1000*1000*1000 mm
- ESC-NVO1000-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO1000-T6: Heating System: Stainless steel high-speed heater
- ESC-NVO1000-T6: Control System: Touchscreen programmable control
- ESC-NVO125-T6: Internal Chamber Dimensions: 500*500*500 mm
- ESC-NVO125-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO125-T6: Heating System: Stainless steel high-speed heater
- ESC-NVO125-T6: Control System: Touchscreen programmable control
- ESC-NVO216-T6: Internal Chamber Dimensions: 600*600*600 mm
- ESC-NVO216-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO216-T6: Heating System: Stainless steel high-speed heater
- ESC-NVO216-T6: Control System: Touchscreen programmable control
- ESC-NVO27-T6: Internal Chamber Dimensions: 300*300*300 mm
- ESC-NVO27-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO27-T6: Safety Devices: Phase-loss protection, Earth-leakage protection, Overload protection, Overtemperature protection, Fault warning indicator
- ESC-NVO27-T6: Optional Accessories: ①Cold trap;②Recorder;③Oil mist filter;④Oxygen analyzer;⑤Dry pump;⑥Communication interface