Key points for selecting ceramic substrate heat treatment equipment
Before choosing operating conditions for ceramic-substrate heat treatment, define the observable material result and the actual load.
For ceramic substrates, check support, warpage and thermal shock and assess a furnace if the process exceeds the oven range.
Equipment decisions
-
Accept oxygen level, time to reach it and hold-stage stability separately; record nitrogen purity, supply pressure and consumption.
-
Define the oxygen sampling location, analyser delay and calibration method. Test with a real load and after door opening; supply-gas purity cannot substitute for chamber oxygen measurements.
-
Confirm the sequence of evacuation, nitrogen admission and heating, and whether the circulation fan can operate in vacuum mode. Screen pressure-sensitive samples on a small load first.
-
Check oxidation and moisture regain during cooling and unloading, together with exhaust routing, gas-supply failure response and site ventilation.
Trial and acceptance
Record the initial sample condition, loading layout, recipe version and raw measurements. Agree the acceptance endpoint before the trial; repeat at challenging load positions and compare the finished material result.
Catalogue comparison
Candidate models in the current catalogue: ESC-NVO1000-T6, ESC-NVO125-T6, ESC-NVO216-T6, ESC-NVO27-T6. These are comparison candidates, subject to the process checks above.
The following specifications apply only to the models listed:
- ESC-NVO1000-T6: Internal Chamber Dimensions: 1000*1000*1000 mm
- ESC-NVO1000-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO1000-T6: Heating System: Stainless steel high-speed heater
- ESC-NVO1000-T6: Control System: Touchscreen programmable control
- ESC-NVO125-T6: Internal Chamber Dimensions: 500*500*500 mm
- ESC-NVO125-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO125-T6: Heating System: Stainless steel high-speed heater
- ESC-NVO125-T6: Control System: Touchscreen programmable control
- ESC-NVO216-T6: Internal Chamber Dimensions: 600*600*600 mm
- ESC-NVO216-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO216-T6: Heating System: Stainless steel high-speed heater
- ESC-NVO216-T6: Control System: Touchscreen programmable control
- ESC-NVO27-T6: Internal Chamber Dimensions: 300*300*300 mm
- ESC-NVO27-T6: Operating Temperature Range: A:Room temperature+25~200℃;B:Room temperature+35~300℃;C:Room temperature+45~400℃;D:Room temperature+50~500℃;E:Room temperature+60~600℃
- ESC-NVO27-T6: Safety Devices: Phase-loss protection, Earth-leakage protection, Overload protection, Overtemperature protection, Fault warning indicator
- ESC-NVO27-T6: Optional Accessories: ①Cold trap;②Recorder;③Oil mist filter;④Oxygen analyzer;⑤Dry pump;⑥Communication interface